If a hood is to be installed above the hob, refer to the hood installation instructions to ensure the correct
height above the hob
Hood and cabinetry clearances (mm)
Injectors table
840
-2
0
480
-2
0
86
0
510
38
min. R 6,5
max R 16
70 min.
Category II2L3B/P
Electric power: 230 V ~ 50 Hz
Type of gas used Type of
burner
Injector label Control
primary air
(X) mm
Nominal
heat flow
kW
Nominal
consumption
Reduced heat flow kW Gas pressure
(mbar)
min. nom. max.
NATURAL GAS
(Methane) G25
wok 154 5,5 4,20 465 l/h 1,55
20 25 30
rapid 132 3,00 332 l/h 0,60
semi-rapid 100 1,65 183 l/h 0,35
auxiliary 79 1,00 111 l/h 0,35
LIQUID PETROLEUM GAS
(Butane) G30
(Propane) G31
wok 95 11 3,80 276 g/h 1,55
25 30 35
rapid 87 3,00 218 g/h 0,60
semi-rapid 67 1,65 120 g/h 0,35
auxiliary 50 1,00 73 g/h 0,35
Type of gas used Configuration model
Nominal heat flow
kW
Overall nominal consumption
Required air (m
3
) for the
combustion 1 m
3
of gas
G25 25 mbar 5 burners 11,50 1274 l/h 8,187
G30-G31 30 mbar 5 burners 11,10 807 g/h 30,94