If a hood is to be installed above the hob, refer to the hood installation instructions to ensure the correct
height above the hob
Hood and cabinetry clearances (mm)
Category
II2H3+
Electric supply: 220-240 V - 50/60 Hz
Injectors table
Type of gas used Type of burner Injector marking Rated thermal
flow rate kW
Rated
consumption
Reduced heat
capacity kW
Gas pressure
(mbar)
min. rat. max.
NATURAL GAS
(Methane) G20
2 ring 136A 3,80 362 l/h 2,20
17 20 25semi-rapid 95 1,65 157 l/h 0,35
auxiliary 78A 1,00 95 l/h 0,30
LIQUID
PETROLEUM GAS
(Butane) G30
2 ring 95A 3,80 276 g/h 1,90
20 28-30 35semi-rapid 67 1,65 120 g/h 0,35
auxiliary 50 1,00 73 g/h 0,30
LIQUID
PETROLEUM GAS
(Propane) G31
2 ring 95A 3,80 271 g/h 1,90
25 37 45semi-rapid 67 1,65 118 g/h 0,35
auxiliary 50 1,00 71 g/h 0,30
Ty p e o f g a s
used
Model
configuration
Rated thermal
flow rate (kW)
Total rated
consumption
Air required (m³) for
burning 1m³ of gas
G20 20 mbar 4 burners 7,80 742 l/h 9,52
G30 28-30 mbar 4 burners 7,80 567 g/h 30,94
G31 37 mbar 4 burners 7,80 557 g/h 23,80